Why is magnetic response not a grade certificate?
ASSDA's Magnetic Effects of Stainless Steels FAQ explains that composition, metallic structure and processing affect magnetic properties. It notes that wrought austenitic 304 and 316 are generally weakly responsive in the annealed condition, while cold working can increase attraction.
That makes magnetic response useful context for a qualified materials question, not a unique grade identifier. Genset Enclosures is independent and is not affiliated with ASSDA. This article does not select an alloy, certify corrosion resistance or recommend heat treatment.
Sources: ASSDA: ASSDA: official reference checked 22 October 2026
Which records belong with the panel?
Trace the item from the approved material requirement to the actual supplied and fabricated part. A generic stainless description does not identify the specified alloy.
| Record | Retain | Review question |
|---|---|---|
| Requirement | Approved grade and finish | What was specified? |
| Supply | Material document and batch | Which material arrived? |
| Part | Panel or component identity | Which record applies? |
| Fabrication | Relevant process record | Has condition changed? |
| Observation | Location and method | What was actually observed? |
| Disposition | Qualified materials decision | Accept, clarify or test? |
What should happen after a surprising observation?
Illustrative example. A fictional formed enclosure door attracts a small magnet near a worked edge. Its receiving sheet says only stainless, and the drawing requires a particular grade. The inspector labels it carbon steel from that observation alone.
The document reviewer records the observation and retrieves the material traceability for that door. The qualified reviewer decides whether the supplied evidence establishes the requirement or whether an appropriate identification method is needed. A magnetic response neither proves the specified grade nor automatically proves a substitution.
How should an unresolved grade be shown on the drawing package?
Keep the material requirement and the open evidence issue visible. Do not alter the specified alloy, erase the observation or copy a certificate from another batch to close the register.
Material identity, surface condition and suitability for the project environment are separate acceptance questions. Engineering sign-off is performed only by the registered engineer on the job.
Common questions
What else should the bid team know?
Does attraction always prove carbon steel?
No. Some stainless steels and worked conditions also attract a magnet.
Does no obvious attraction prove grade 316?
No. Magnetic response is not a unique grade identifier.
Can the drawing team certify the alloy?
No. Retain the evidence and obtain the responsible qualified review.