What does the reference establish?
Rogers Corporation's 8 August 2024 explanation of elastomeric foam compression set distinguishes calculations that include the compressed-height spacer from those that do not. It also identifies test and recovery conditions as necessary context. Its material discussion does not specify an acceptable result for a generator-enclosure door gasket.
Genset Enclosures is independent and is not affiliated with Rogers Corporation. Obtain the actual gasket supplier's approved definitions, geometry and test evidence. A material data-sheet percentage alone does not prove assembled enclosure sealing performance.
Sources: Rogers Corporation: Compression set for elastomeric foam materials, 8 August 2024
Which definitions belong in the drawing review?
Keep the installed gap and approved gasket profile separate from a laboratory material result. Record the supplier's calculation basis because percentages based on original thickness and original deflection are different.
| Field | Evidence | Review |
|---|---|---|
| Original height | Uncompressed specimen or profile basis | Match the supplier definition |
| Compressed height | Actual defined gap or test height | Separate test and installation |
| Recovered height | Measurement after specified recovery | Retain recovery conditions |
| Set result | Formula and denominator used | Do not call it squeeze |
| Conditions | Material, time, temperature and medium | Compare only compatible tests |
| Assembly | Approved joint and performance evidence | Do not infer an enclosure rating |
How can the same heights give different percentages?
Illustrative example. A fictional specimen starts at 8 mm, is held at 6 mm and recovers to 7.5 mm under assumed test conditions. Initial compression relative to original height is (8 - 6) / 8 = 25 percent. Compression set relative to the original 2 mm deflection is (8 - 7.5) / (8 - 6) = 25 percent.
The equal percentages are coincidental: they describe different differences and denominators. The permanent height loss is 0.5 mm, or 6.25 percent of the original height. These invented values are not a recommended squeeze, permissible set, test procedure or prediction of seal life.
What should stay open when evidence is incomplete?
Request the actual material grade, profile, approved joint gap and compatible test report. Refer an unexplained denominator or changed material to the enclosure and seal design owners. Do not adjust hinges or latch force to make a laboratory percentage match a drawing.
This worksheet supplies no ingress, acoustic or durability certification. Engineering sign-off is performed only by the registered engineer on the job.
Common questions
What else should the bid team know?
Is compression set the installed squeeze?
No. Keep their definitions and denominators separate.
Does a material percentage prove an enclosure rating?
No. Assembly performance requires its own approved evidence.
Is 25 percent a design recommendation here?
No. It is arithmetic in a fictional example.
Primary sources
- Compression set for elastomeric foam materials, 8 August 2024Rogers Corporation